{"id":1479,"date":"2021-03-04T03:18:24","date_gmt":"2021-03-04T03:18:24","guid":{"rendered":"http:\/\/yeouday.com\/?post_type=product&#038;p=1479"},"modified":"2021-03-12T05:19:24","modified_gmt":"2021-03-12T05:19:24","slug":"koso-ep1000-%e6%b0%a3%e5%8b%95%e5%ae%9a%e4%bd%8d%e5%99%a8","status":"publish","type":"product","link":"https:\/\/yeouday.com\/en\/product\/koso-ep1000-%e6%b0%a3%e5%8b%95%e5%ae%9a%e4%bd%8d%e5%99%a8\/","title":{"rendered":"KOSO EP1000  Electro-Pneumatic Positioner"},"content":{"rendered":"<h4>\n<table id=\"tablepress-3\" class=\"tablepress tablepress-id-3\">\n<tbody class=\"row-hover\">\n<tr class=\"row-1 odd\">\n\t<td class=\"column-1\">Series<\/td><td class=\"column-2\">EP1000<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-2 even\">\n\t<td class=\"column-1\">Applicable Actuators<\/td><td class=\"column-2\">Single and double acting actuators<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-3 odd\">\n\t<td class=\"column-1\">Input Signal<\/td><td class=\"column-2\">4 to 20mA DC (adjustable to 1\/4 split range)<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-4 even\">\n\t<td class=\"column-1\">Power supply<\/td><td class=\"column-2\">2-Wire type<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-5 odd\">\n\t<td class=\"column-1\">Input impedance<\/td><td class=\"column-2\">500\u03a9 at 20mA (Input voltage less than 10V)<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-6 even\">\n\t<td class=\"column-1\">Characteristic<\/td><td class=\"column-2\">Linear (Desired characteristic settable)<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-7 odd\">\n\t<td class=\"column-1\">Pilot valve<\/td><td class=\"column-2\">Non-bleeding type<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-8 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Single acting and double acting types are available<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-9 odd\">\n\t<td class=\"column-1\">Air supply<\/td><td class=\"column-2\">140 to 700kPa<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-10 even\">\n\t<td class=\"column-1\">Air consumption<\/td><td class=\"column-2\">Output air pressure 50%<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-11 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">5Nl\/min at 140kPa air supply<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-12 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">15Nl\/min at 400kPa air supply<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-13 odd\">\n\t<td class=\"column-1\">Max. capacity<\/td><td class=\"column-2\">Capacity when output is atmospheric venting<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-14 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">175Nl\/min at 140kPa air supply<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-15 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">400Nl\/min at 400kPa air supply<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-16 even\">\n\t<td class=\"column-1\">Performance<\/td><td class=\"column-2\">For single acting actuator<\/td><td class=\"column-3\">For double acting actuator<\/td>\n<\/tr>\n<tr class=\"row-17 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Linearity : +\/-1.0% of FS.<\/td><td class=\"column-3\">Linearity : +\/-1.5% of FS.<\/td>\n<\/tr>\n<tr class=\"row-18 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Hysteresis : 0.5% of FS.<\/td><td class=\"column-3\">Hysteresis : 0.8% of FS.<\/td>\n<\/tr>\n<tr class=\"row-19 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Response level : 0.1% of FS.<\/td><td class=\"column-3\">Response level : 0.2% of FS.<\/td>\n<\/tr>\n<tr class=\"row-20 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Repeatability : 0.2% of FS.<\/td><td class=\"column-3\">Repeatability : 0.3% of FS.<\/td>\n<\/tr>\n<tr class=\"row-21 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">The above represents the performance of the positioner on an actuator without a valve. For the performance of the complete unit with a valve and an actuator, see KOSO STANDARD SPECIFICATION.<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-22 even\">\n\t<td class=\"column-1\">Calibration<\/td><td class=\"column-2\">1 button calibration<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-23 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Calibration by positioner alone.<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-24 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Own program<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-25 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">with Note PC or Disktop PC<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-26 even\">\n\t<td class=\"column-1\">Self diagnosis items<\/td><td class=\"column-2\">Air supply check\/Eath unit's function check\/Over load check<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-27 odd\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Fail position for breakdown selectable<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-28 even\">\n\t<td class=\"column-1\">Air connection<\/td><td class=\"column-2\">Rc 1\/4<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-29 odd\">\n\t<td class=\"column-1\">wiring connection<\/td><td class=\"column-2\">G 1\/2<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-30 even\">\n\t<td class=\"column-1\">Ambient temperature<\/td><td class=\"column-2\">Standard type : -20 to 80\u00b0, Explosion type : -20 to 60\u00b0<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-31 odd\">\n\t<td class=\"column-1\">Ambient humidity range<\/td><td class=\"column-2\">10 to 90% RH<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-32 even\">\n\t<td class=\"column-1\">Enclosure<\/td><td class=\"column-2\">Weather proof type (IP65), Explosion proof type (ExdCT6)<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-33 odd\">\n\t<td class=\"column-1\">Standard anicillary<\/td><td class=\"column-2\">Auto-Manual change<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-34 even\">\n\t<td class=\"column-1\">Housing material<\/td><td class=\"column-2\">Aluminum alloy<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-35 odd\">\n\t<td class=\"column-1\">Coating<\/td><td class=\"column-2\">Epoxy resin group paint<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-36 even\">\n\t<td class=\"column-1\">Coating colors<\/td><td class=\"column-2\">Body : Dark green, Cover : Light gray<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-37 odd\">\n\t<td class=\"column-1\">Apporox. Weight<\/td><td class=\"column-2\">2.6kg<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-38 even\">\n\t<td class=\"column-1\">Optional specifications<\/td><td class=\"column-2\">Available upon request<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-39 odd\">\n\t<td class=\"column-1\">Position transmitter<\/td><td class=\"column-2\">4 to 20mA 2-Wire type<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-40 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Power source required in addition to input signal.<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-41 odd\">\n\t<td class=\"column-1\">Limit switches<\/td><td class=\"column-2\">Open\/Shut<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-42 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Open collector type<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-43 odd\">\n\t<td class=\"column-1\">Self diagnosis indication<\/td><td class=\"column-2\">diagnosis result on LED<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-44 even\">\n\t<td class=\"column-1\"><\/td><td class=\"column-2\">Separate power supply required<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-45 odd\">\n\t<td class=\"column-1\">wiring connection<\/td><td class=\"column-2\">1\/2 NPT<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-46 even\">\n\t<td class=\"column-1\">Air connection<\/td><td class=\"column-2\">1\/4 NPT<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-3 from cache --><\/h4>\n<p>&nbsp;<\/p>\n<h4><\/h4>\n<p>&nbsp;<\/p>\n<pre><a href=\"https:\/\/yeouday.com\/en\/contact-us\/\"><strong>Feel free to reach out if you have any questions or need more details and information.<\/strong><\/a><\/pre>\n<h4 class=\"p1\"><\/h4>\n<p>&nbsp;<\/p>","protected":false},"excerpt":{"rendered":"<p><span style=\"color: #808080;\"><strong>EP1000: Electro-Pneumatic Positioner<\/strong><\/span><\/p>\n<div id=\"gtx-trans\" style=\"position: absolute; left: 367px; top: 31px;\">\n<div class=\"gtx-trans-icon\"><\/div>\n<\/div>","protected":false},"featured_media":1598,"template":"","meta":[],"_links":{"self":[{"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/product\/1479"}],"collection":[{"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/types\/product"}],"version-history":[{"count":12,"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/product\/1479\/revisions"}],"predecessor-version":[{"id":1610,"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/product\/1479\/revisions\/1610"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/media\/1598"}],"wp:attachment":[{"href":"https:\/\/yeouday.com\/en\/wp-json\/wp\/v2\/media?parent=1479"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}